Description:
Biotin Nanoselector® Magnetic beads IP Kit is designed for IP(immunoprecipitation) or Co-IP experiment. This kit consist of Biotin Nanoselector® Magnetic beads and related supporting reagents.
Biotin Nanoselector® Magnetic beads have been specifically designed to bind biotinylated proteins. Biotin Nanoselector® Magnetic beads are based on small high-affinity recombinant single domain antibody covalently coupled to the surface of Magnetic beads. Biotin Nanoselector Magnetic beads are ideal tools to isolate or purify biotinylated proteins fast and efficiently.
Properties
Ligand | Anti-biotin single domain antibody fragment (VHH, Nanobody) |
Reactivity | Specifically binds to biotinylated protein. |
Binding capacity | 50-100 µg of biotinylated Mouse IgG protein per 10 µL bead slurry |
Bead size | ~ 40 µm |
Storage buffer | 10mM PBS (pH 7.5), 0.01% proclin300 |
Storage conditions | Upon receipt store at +4°C. Do not freeze! |
Stability | Stable for 1 year upon receipt. |
Shipment | Shipped at low temperature(2-8℃) |
Main Components of The Kit
Name | Composition | Quantity | Storage |
Biotin Magnetic beads | 50% Magnetic beads slurry, 10mM PBS pH 7.5, 0.01% proclin300(Code: 078-101-003) | 500 uL | 4 ℃ |
Binding Control Magnetic beads | 50% Magnetic beads slurry, 10mM PBS pH 7.5, 0.01% proclin300(Code: 100-100-200) | 500 uL | 4 ℃ |
Lysis buffer | 10mM Tris-HCl pH7.5,150mM NaCl, 0.5%NP40, 0.5mM EDTA | 20 mL | 4 ℃ |
Wash buffer | 10mM Tris-HCl pH7.5, 150mM NaCl, 0.05% NP40, 0.5mM EDTA | 120 mL | 4 ℃ |
Acidic elution buffer | 0.2M Glycine-HCl pH 2.5 | 10 mL | 4 ℃ |
Neutralization buffer | 1M Tris-HCl pH 10.4 | 1 mL | 4 ℃ |
2xSDS Sample buffer | 120mM Tris-HCL pH6.8, 20% Glycerol, 4% SDS, 0.04% bromophenol blue, 10% β-mercaptoethanol | 2.5 mL | Room Temperature |
5x TBST | 0.1M Tris-HCl pH7.5, 2.5M NaCl, 0.5% Tween-20, 0.5% ProClin300 | 60 mL | 4 ℃ |
Positive Control (Biotin-mNeongreen)* | Biotin-mNeongreen in Lysis buffer | 1 mL | 4 ℃ |
*Note:
1. When using a Positive Control, please add 500ul of Positive Control/25 ul magnetic beads to each IP reaction.
2. Please ensure that the tube cover is tightly closed after each use to avoid affecting the performance of the reagent.
3. Each component needs to be stored under appropriate temperature conditions.
Product Application:
Immunoprecipitation(IP), Co-immunoprecipitation(CO-IP), Enzyme activity detection, Mass spectrometry analysis (MS), etc.
Note: Please refer to the instruction manual for usage instructions.