Biotin Nanoselector® Magnetic beads IP Kit

Biotin Nanoselector® Magnetic beads IP Kit
Biotin Nanoselector® Magnetic beads IP Kit

Details and Advantages

Code: 078-101-003K

Specification: 20X Test

Applications: IP

Reactivity: Biotin

Conjugate:

Advantages:

  • Consistent and reproducible results

  • No heavy & light antibody chains

  • Extraordinarybinding,even under harsh conditions

  • High affinity and Short incubation (5-30min)

Product Detail

Product Detail

Description:

Biotin Nanoselector® Magnetic beads IP Kit is designed for IP(immunoprecipitation) or Co-IP experiment. This kit consist of Biotin Nanoselector® Magnetic beads and related supporting reagents.

Biotin Nanoselector® Magnetic beads have been specifically designed to bind biotinylated proteins. Biotin Nanoselector® Magnetic beads are based on small high-affinity recombinant single domain antibody covalently coupled to the surface of Magnetic beads. Biotin Nanoselector Magnetic beads are ideal tools to isolate or purify biotinylated proteins fast and efficiently.


Properties

Ligand

Anti-biotin single domain antibody fragment (VHH, Nanobody)

Reactivity

Specifically binds to biotinylated protein.

Binding capacity

50-100 µg of biotinylated Mouse IgG protein per 10 µL bead slurry

Bead size

~ 40 µm

Storage buffer

10mM PBS (pH 7.5), 0.01% proclin300

Storage conditions

Upon receipt store at +4°C. Do not freeze!

Stability

Stable for 1 year upon receipt.

Shipment

Shipped at low temperature(2-8)


Main Components of The Kit

Name

Composition

Quantity

Storage

Biotin Magnetic beads

50% Magnetic beads slurry, 10mM PBS pH 7.5, 0.01% proclin300(Code: 078-101-003)

500 uL

4 ℃

Binding Control 

Magnetic beads

50% Magnetic beads slurry, 10mM PBS pH 7.5, 0.01% proclin300Code: 100-100-200

500 uL

4 ℃

Lysis buffer

10mM Tris-HCl pH7.5,150mM NaCl, 0.5%NP40, 0.5mM EDTA

20 mL

4 ℃

Wash buffer

10mM Tris-HCl pH7.5, 150mM NaCl, 0.05% NP40, 0.5mM EDTA

120 mL

4 ℃

Acidic elution buffer

0.2M Glycine-HCl pH 2.5

10 mL

4 ℃

Neutralization buffer

1M Tris-HCl pH 10.4

1 mL

4 ℃

2xSDS Sample buffer

120mM Tris-HCL pH6.8, 20% Glycerol, 4% SDS, 0.04% bromophenol blue, 10% β-mercaptoethanol

2.5 mL

Room Temperature

5x TBST

0.1M Tris-HCl pH7.5, 2.5M NaCl, 0.5% Tween-20, 0.5% ProClin300

60 mL

4 ℃

Positive Control 

(Biotin-mNeongreen)*

Biotin-mNeongreen in Lysis buffer

1 mL

4 ℃

*Note:

1. When using a Positive Control, please add 500ul of Positive Control/25 ul  magnetic beads to each IP reaction.

2. Please ensure that the tube cover is tightly closed after each use to avoid affecting the performance of the reagent.

3. Each component needs to be stored under appropriate temperature conditions.


Product Application:

Immunoprecipitation(IP), Co-immunoprecipitation(CO-IP), Enzyme activity detection, Mass spectrometry analysis (MS), etc.

Note: Please refer to the instruction manual for usage instructions.

FAQ

Citations

Related Products

Consult

Contact

Telephone:

+86 138 8067 6215