Description:
GFP Nanoselector® Magnetic beads IP Kit is designed for IP(immunoprecipitation) or Co-IP experiment. This kit consist of GFP Nanoselector® Magnetic beads and related supporting reagents.
The GFP Nanoselector® Magnetic beads consists of an anti-Green Fluorescent Protein (GFP) Nanobody (VHH), which is covalently bound to magnetic beads. GFP Nanoselector® Magnetic beads is used to immunoprecipitate GFP-fusion proteins from cell extracts of various organisms like mammals, plants, bacteria, yeast, insects etc. The GFP Nanoselector® Magnetic beads has great advantages such as high load capacity and no light or heavy chain interference.
Properties
Ligand | Anti-GFP single domain antibody fragment (VHH, Nanobody) |
Reactivity | Specifically binds to GFP,mEGFP, superfolder GFP, CFP, YFP and common GFP derivatives |
Binding capacity | 20 µg of recombinant GFP per 10 µL bead slurry |
Bead size | ~ 40 µm |
Storage buffer | 10mM PBS (pH 7.5), 0.01% proclin300 |
Storage conditions | Upon receipt store at +4°C. Do not freeze! |
Stability | Stable for 1 year upon receipt. |
Shipment | Shipped at low temperature(2-8℃) |
Main Components of The Kit
Name | Composition | Quantity | Storage |
GFP Nanoselector® Magnetic beads | 50% Magnetic beads slurry, 10mM PBS pH 7.5, 0.01% proclin300(Code: 019-101-003) | 500 uL | 4 ℃ |
Binding Control Magnetic beads | 50% Magnetic beads slurry, 10mM PBS pH 7.5, 0.01% proclin300(Code: 100-100-200) | 500 uL | 4 ℃ |
Lysis buffer | 10mM Tris-HCl pH7.5,150mM NaCl, 0.5%NP40, 0.5mM EDTA | 20 mL | 4 ℃ |
Wash buffer | 10mM Tris-HCl pH7.5, 150mM NaCl, 0.05% NP40, 0.5mM EDTA | 120 mL | 4 ℃ |
Acidic elution buffer | 0.2M Glycine-HCl pH 2.5 | 10 mL | 4 ℃ |
Neutralization buffer | 1M Tris-HCl pH 10.4 | 1 mL | 4 ℃ |
2xSDS Sample buffer | 120mM Tris-HCL pH6.8, 20% Glycerol, 4% SDS, 0.04% bromophenol blue, 10% β-mercaptoethanol | 2.5 mL | Room Temperature |
5x TBST | 0.1M Tris-HCl pH7.5, 2.5M NaCl, 0.5% Tween-20, 0.5% ProClin300 | 60 mL | 4 ℃ |
Positive Control (GFP-his)* | GFP-his in Lysis buffer | 1 mL | 4 ℃ |
*Note:
1. When using a Positive Control, please add 500ul of Positive Control/25 ul magnetic beads to each IP reaction.
2. Please ensure that the tube cover is tightly closed after each use to avoid affecting the performance of the reagent.
3. Each component needs to be stored under appropriate temperature conditions.
Product Application:
Immunoprecipitation(IP), Co-immunoprecipitation(CO-IP), Enzyme activity detection, Mass spectrometry analysis (MS), etc.
Note: Please refer to the instruction manual for usage instructions.